⚙️ Elevate your automation game with silent, powerful switching!
The CG Solid State Relay SSR-100DD is a robust single-phase relay designed for industrial automation, offering 100A switching capacity and a wide input control voltage range of 3-32V DC. Its flame-retardant plastic housing and included thermal grease ensure durability and efficient heat management, while zero voltage switching guarantees silent, spark-free operation. Ideal for temperature controllers and machinery control systems in demanding environments.


































| ASIN | B08GP328LH |
| Brand | CGELE |
| Coil Voltage | 32 Volts (DC) |
| Connector Type | Screw |
| Contact Current Rating | 100 Amps |
| Contact Material | Silver |
| Contact Type | Normally Open |
| Current Rating | 100 Amps |
| Customer Reviews | 4.0 4.0 out of 5 stars (248) |
| Manufacturer | CGELE |
| Maximum Switching Current | 100 Amps |
| Maximum Switching Voltage | 240 Volts |
| Minimum Switching Voltage | 3 Volts (DC) |
| Mounting Type | Screw Mount |
| Operation Mode | Automatic |
| Specification Met | Electromagnetic Compatibility |
| UPC | 774297736460 |
| Wattage | 24000 watts |
M**Z
No funciona como un relavador normal energizado o no este se mantiene activado
J**S
Im using one of these 40 amp SSRs to PWM a transmission cooler fan up under my jeep. Been installed for about a year now and so far no issues. If you use it to control a motor you have to run a fly back diode to keep from ruining the SSR. Thats what the 3 black rectangles with red a black wires running to them are. Gonna buy another one of these to pwm a windshield washer pump for water injection pre turbo (cheap turbo, dont care about the compressor wheel)
M**A
This is an excellent relay, works perfectly and little noise (40db or so) when turning on
N**.
Great contactless and silent relay, this will last forever if its well configured and silicone paste applied for heath transfer
J**R
100 amp SSR: I measured an internal resistance of 0.25 ohm with a 5 amp load current. For small currents, the resistance is approximately linear. If I tried to run 10 amps through it, it would dissipate 25 watts and drop 2.5 volts (if the resistance stays linear). A good heat sink is required. If I tried to use it with a 50 amp load current, it would either melt or burn up trying to dissipate over 600 watts. This SSR is only useable at 10% of its load rating. Observe the polarity markings. Current must flow from + to - within the relay. Warning: It's a short circuit if wired backwards. The device will not operate properly with an AC load; it acts like a diode. I've tested a dozen of the 25A relays, and they all have the same internal resistance characteristic as this 100A unit.
Trustpilot
Hace 3 semanas
Hace 1 semana